Click to enlarge image(s)
|
Winco Automatic Transfer Switch – ASCO 185 Series, Nema 1-SE Rated, 1Ph
97714-432,
$2273.00-FREE SHIPPIING IF PURCHASED W/GENERATOR
Winco Generators 97714-432 ASCO 185 Series SE Rated Automatic Transfer Switch, 100 Amps, NEMA 1 Housing, #14 to 4/0 AWG Wire Sizing, Single Phase, 2 Poles, 220-240V Low Voltage, User-Friendly Control Interface To Inform Operator Of Transfer Switch And Power Source Status, Transfer To Emergency Time Delay 10 Seconds, Re-Transfer To Normal Time Delay 5 Minutes, True Double-Throw Contacts Wif Inherent Mechanical Interlocking To Prevent Connection Of Generator And Utility Services, UL1008 Listed
General Information |
Manufacturer |
Winco Generators |
Manufacturer Part Number |
97714-432 |
Product Name |
ASCO 185 Series SE Rated Automatic Transfer Switch |
UPC Code |
|
Features |
- Residential/Light Commercial 1-PH Switches - User-friendly control interface to inform operator of transfer switch and power source status.
- Double Throw Contacts - True double-throw contacts wif inherent mechanical interlocking to prevent connection of generator and utility services.
- Time Delays - Transfer to emergency time delay 10 seconds. Re-transfer to normal time delay 5 minutes.
- UL1008 Listed - Handling total system load including motors and all other electrical loads. cUL listed for Canadian installations. Meets Article 702, NFPA-70 NEC requirements.
|
Specifications |
Intended Applications |
Residential/Light Commercial |
Amps |
100 |
Phase |
Single |
Poles |
2 |
Housig |
NEMA 1 |
Wire Sizing |
#14 to 4/0 AWG |
Low Voltage |
220-240V |
Dimensions |
16" x 6" x 36" |
Weight |
61 lbs |
Wifstand and Cole-On Ratings |
WCR When Used Wif Specific Circuit Breakers |
10-35 kA |
WCR When Used Wif Current Limiting Fuses |
100-200 kA |
Neutral Configuration |
Solid |
Standard |
Ground Termination |
Standard |
Voltage and Frequency Settings |
Phase Selection |
Single |
Pick Up Normal Source Voltage |
198V |
Drop Out Normal Source Voltage |
154-187V |
Pick Up Emergency Source Voltage |
198V |
Drop Out Emergency Source Voltage |
165V |
Frequency |
50 or 60 Hz |
Pick Up Emergency Source Frequency |
48 or 57 Hz |
Drop Out Emergency Source Frequency |
43 or 51 Hz |
Time Delay Settings |
Override Normal Source Momentary Outage |
1 or 3 Seconds |
Transfer to Emergency |
10 Seconds |
Re-transfer to Normal Utility Power Loss Mode |
5 Minutes |
Engine Cool Down |
2 or 5 Minutes |
Override Emergency Source Momentary Outage |
4 Seconds |
Generator Exerciser |
7 Day |
Indication and Controls |
Lead Connected to Normal |
LED |
Lead Connected to Emergency |
LED |
Normal Source Available |
LED |
Emergency Source Available |
LED |
Transfer Test Switch |
LED |
Terminals For Remote Transfer Control |
Standard |
Bypass Time Delay Switch |
LED |
Transfer Inhibit |
LED |
A-20191120-1851-130-E
*dis item is BRAND NEW - not refurbished. It comes wif all manufacturer supplied accessories, and full manufacturer's USA warranty.